Advertisement
Am J Health-Syst Pharm
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Twardowski, Z.
Right arrow Articles by Slimack, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Twardowski, Z.
Right arrow Articles by Slimack, W.
American Journal of Hospital Pharmacy, Vol 40, Issue 4, 575-579
Copyright © 1983 by American Society of Health-System Pharmacists


Articles

Insulin binding to plastic bags: a methodologic study

ZJ Twardowski, KD Nolph, TJ McGary, HL Moore, P Collin, RK Ausman, and WS Slimack


A radiotracer method to assess insulin binding to commercially available plastic peritoneal dialysis solution containers was developed. A peritoneal dialysis bag (bag 2) was emptied and attached to another full bag (bag 1) of the same kind. In the syringe-to-bag method, bag 1 was symmetrically injected through the bag wall with four syringes containing dialysis solution and radioactive insulin, with or without regular insulin. The radioactivity in each syringe was measured with a gamma counter before injection, and all of the samples were counted afterwards directly in the syringes. Using a bag-to-bag transfer method, bag 1 was agitated, eight samples were taken from different parts through the wall, and then the contents were transferred to bag 2. Bag 2 was then agitated and eight samples were taken and counted. In the bag-pieces method, pieces of bag wall were cut and the radioactivity on the walls was measured to determine the amount of binding. The syringe-to-bag method gave negative results, severely underestimating the amount of insulin binding. The bag-to-bag transfer method yielded positive results in all instances. Increasing the amounts of regular insulin had no demonstrable impact on percent of binding. When the bag-to-bag method was compared with the bag-pieces method, it gave only slightly higher values; however, the bag-to-bag method was considered more reliable because the counting can be controlled more effectively. A 15-minute delay in sampling was not found to influence insulin binding. A reliable method of assessing insulin binding must be based on the following two principles: (1) The transfer of samples to intermediate containers should be avoided, and (2) radiotracer concentrations in the samples should be similar.
 



This article has been cited by other articles:


Home page
The Diabetes EducatorHome page
J. Ung, M. Hu, T. Hagerup, and R. K. Campbell
Lispro Insulin: Adsorption and Stability in Selected Intravenous Devices
The Diabetes Educator, March 1, 1999; 25(2): 237 - 245.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
B. Dunham and S. P. Marcuard
Availability of Insulin from TPN Solutions
JPEN J Parenter Enteral Nutr, July 1, 1991; 15(4): 497 - 497.
[PDF]


Home page
JPEN J Parenter Enteral NutrHome page
B. Dunham and S. P. Marcuard
Availability of Insulin from TPN Solutions
JPEN J Parenter Enteral Nutr, July 1, 1990; 14(4): 434 - 434.
[PDF]


Home page
JPEN J Parenter Enteral NutrHome page
S. P. Marcuard, B. Dunham, A. Hobbs, and J. F. Caro
Availability of Insulin from Total Parenteral Nutrition Solutions
JPEN J Parenter Enteral Nutr, May 1, 1990; 14(3): 262 - 264.
[Abstract] [PDF]